Functional features
●Support languages: CHN ENG RUS FREN GER PORTU SPAN
●lead synchronous ECG acquisition;
●equipped with high speed and high sensitivity hot spot recording system, with print trace depth adjustment function;
● 10.2-inch high-definition and wide-angle color LCD screen, capacitive touch control, 12-lead display;
● six ECG record combination modes;
● single line /3 channel/(3+R) channel/(+l+V5) channel/double line 6 channel/single line 6 channel/single/double line 12 channels eight ECG display combination mode;
● accurate ECG automatic diagnosis function, with heart rate exceeding alarm function, and set whether to print the measurement and analysis report;
● full keyboard Chinese touch input (pinyin and wubi optional), can enter hospital and patient information;
● with real-time ECG waveform freezing function, it is easy to grasp the patient’s important ECG waveform;
● manual, automatic, rhythm, physical examination and other operating modes;
● with RS232 communication interface, USB interface and LAN network interface;
● external large capacity SD card /USB memory, can achieve the storage, playback and printing of historical data on the computer;
● built-in large capacity any ion rechargeable battery, and a special charging circuit and perfect battery management and protection system;
● with lead off detection function, with paper shortage detection function;
● wide power supply design, suitable for 110-230, 50/60hz ac power supply.
● memory capacity can be expanded by U disk /SD card.
★ can be connected to the ECG workstation, with a strong patient file management function, can store up to hundreds of thousands of ECG reports;
★ 12-lead automatic ECG analysis system: ECG automatic diagnosis function, automatic ECG measurement and analysis for doctors’ reference;
★ high resolution thermal matrix printout; Baseline stability test to ensure a neat and beautiful ECG waveform every time;
Technical indicators
Common mode rejection ratio | ≥100dB | |
The input circuit | Float, defibrillation | |
Input loop current | ≤0.1чA | |
Sampling rate | 12bit/1000HZ | |
Operating mode | Manual/automatic | |
The filter | Working filter, electromechanical filter | |
Drift filtering | Anti-drift system | |
The input impedance | >50MΩ | |
Patient leakage current | <10чA | |
Fuse specification | T1.6A/ 250V Ø5×20 | |
Recording paper specification | Scroll/folding thermal recording paper (210mm ~ 216mm self-adaptive) | |
Calibration voltage | 1mV±3% | |
Polarization resistance voltage | ±500m V | |
Time constant | ≥3.2s | |
Frequency response | 0.05Hz ~ 165Hz | |
Noise level | ≤15чVp-p | |
Minimum detection signal | ≤20чV | |
The feeding speed | 12.5 mm/s、25mm/s、 50mm/s | |
The sensitivity | 5,10,20 (mm/mV ±5 %) | |
record | Twelve high resolution thermal print | |
The battery | 14.52V/5.2Ah(75.504Wh) | |
Overall dimensions | 365mm×306mm×109mm | Net weight: 4.25 KG |
Size of packing box | 400mm×350mm×200mm | Gross weight: 6.2 KG |